22uF Coupling Capacitor

Share:         
Price: Negotiable
Delivery Date: Within after your order is confirmed.
Place Of Origin USA
Enquiry
Company Profile
 
 
  • Description
  • The Columbia Series 5820 Charge Amplifiers are designed for use with virtually all piezoelectric transducers to form various airborne vibration and shock data acquisition systems. These devices feature a very small package size and extremely low power consumption.

    The Series 5820 Charge Amplifiers provide dual signal outputs, one biased around +2.50VDC and one unbiased capacitance coupled, and are available in seven standard chare conversion ranges, each offering a 10:1 tandem gain adjustment capability. A range of seven low-pass filters are available to meet your individual vibration measurement needs.

    Consult the factory for customizes versions of these sensors.

    Notes:

    Exports from the United States are subject ti the licensing requirements of the Export Administration Regulations (EAR) and/or Internation Traffic in Arms Regulations (TAR)

    Specifications

    Output Impedance Biased: 100Ω Max., Direct Coupled, Unbiased: 100Ω Maimum, 22uF Coupling Capacitor, 20K Internal Load

    Overload Recovery 5000pcmb 1mS Half-Sine, No Effect

    Input Connection Single Ended, Referenced to Circuit Board

    Input Resistance 25Ω Min

    Input Source Capacitance 10000pF Max. to meet all specifications

    Output DC Bias +2.500 +0.075VDC @ Biased Output, 0.000+0.050/-0.000VDC @ Unbiased Output